The Jefferson County Public Sewer District (JCPSD) is issuing a Request for Qualifications (RFQ) from qualified engineering firms to develop a comprehensive Capital Improvement Plan (CIP) for the Festus Crystal City wastewater service area.

Project Background:

The Festus Crystal City wastewater service area is a critical component of JCPSD’s infrastructure. The aging infrastructure requires upgrades and improvements to guarantee continued efficient operation, maintain regulatory compliance, and accommodate projected growth within the service area.

Project Scope:

The selected engineering firm will be responsible for the following:

  • Comprehensive System Assessment: Conduct a thorough evaluation of the existing wastewater collection and treatment systems within the Festus Crystal City service area. This includes infrastructure condition, treatment capacity, and operational efficiency.
  • Needs Identification and Prioritization: Identify current and future needs of the wastewater system, considering factors such as projected growth, regulatory requirements, and potential environmental impact.
  • Development of a Prioritized Capital Improvement Plan: Develop a detailed CIP outlining specific capital improvement projects, their estimated costs, a recommended implementation timeline, and potential funding sources.

Selection Criteria:

JCPSD will select the engineering firm based on the following factors:

  • Proven experience in developing comprehensive Capital Improvement Plans for wastewater systems.
  • Project understanding and approach.
  • Project management and communications
  • Understanding of the region and Project context.

Submission Requirements:

Interested engineering firms must submit the following materials electronically to [Email Address] no later than July 19, 2024

  • Letter of Interest: A concise letter outlining your firm’s qualifications and experience relevant to this specific project.
  • Statement of Qualifications (SOQ): A detailed SOQ outlining your proposed project team, including relevant expertise, project approach, and implementation methodology.
  • Client References: References from at least three prior clients for similar wastewater system Capital Improvement Plan projects.

Selection Process:

JCPSD will evaluate submitted materials to shortlist qualified firms. Shortlisted firms may be invited for an interview to further discuss their qualifications and approach.

JCPSD reserves the right to reject any and all proposals.

We look forward to receiving your qualifications for this important project.

RFQ Festus Crystal City WWTF